Cleanroom Construction Cost: Class 100,000

Table of Contents

Cleanroom Construction Cost: Class 100,000

According to regional environmental and air cleanliness requirements, cleanrooms are usually classified into different levels, including Class 100, Class 1000, Class 10000, Class 100000, and Class 300000. The smaller the value, the higher the cleanliness level. So how much capital is needed to build a 100000 level dust-free workshop? The cost is influenced by various factors, and Baihong Purification now provides a professional explanation on “Cleanroom Construction Cost: Class 100,000“:

Factors Influencing Class 100,000 Cleanroom Construction Cost:

1. Cleanliness level:
There are significant differences in technical requirements and construction costs between Class 100 and Class 100000 clean workshops. The higher the cleanliness level, the higher the unit area cost. Enterprises should choose appropriate cleanliness levels based on actual production process requirements and budget.

2. Workshop scale:
The area of the clean room is an important factor affecting the overall cost, and the larger the area, the higher the construction cost.

Cleanroom Construction

3. Material and equipment selection:
Under the same area conditions, the brand and quality of the selected building materials, air conditioning systems, filtration equipment, etc. will directly affect the final quotation. It is recommended that enterprises prioritize the selection of equipment and materials with stable performance and reliable quality during construction.

4. Industry differences:
There are differences in the requirements for clean environments in different industries. Some products rely on clean systems for production, while others do not. Therefore, the specific use will also affect the overall design and investment.

Class 100,000 Cleanroom Construction: Key Technical Standards

1. Dust particle control
The number of particles ≥ 0.5 μ m per cubic meter of air shall not exceed 3500000; The number of particles ≥ 5 μ m shall not exceed 20000.

2. Microbial limit
The number of planktonic bacteria should not exceed 500 per cubic meter; The number of settling bacteria should not exceed 10 per culture dish.

3.Pressure difference requirement
Uniform pressure difference should be maintained in areas of the same cleanliness level; The pressure difference between adjacent areas of different cleanliness levels should be ≥ 5Pa, and between clean and non clean areas should be ≥ 10Pa.

4.Temperature and Humidity Control
Unless there are special process requirements, the temperature is generally controlled at 20-22 ℃ in autumn and winter, 24-26 ℃ in spring and summer, with a fluctuation range of ± 2 ℃; Relative humidity is 30-50% in autumn and winter, and 50-70% in spring and summer.

The above is a brief introduction to “Cleanroom Construction Cost” from Baihong Purification. Thank you very much for watching. If you need further information or have specific requirements, please feel free to consult Baihong Purification’s customer service. We will provide you with professional services.

Send Your Inquiry Today
滚动至顶部

Submit a Quick Quote